Casa> Blog> Maintainance of multi-bag filter element baghouse

Maintainance of multi-bag filter element baghouse

November 16, 2020
Multi-bag filter cartridge maintenance method When the filter cartridge is used to meet the design flow rate (the pressure gauge difference is 0.1 MPa before and after the flow rate drops significantly), please turn off the filter from the filter, remove the filter cartridge from the filter, rinse the surface with water, and then first Soak in 4% hydrochloric acid for 24 hours, then soak in 4% sodium hydroxide for 24 hours, then rinse with water (two O-rings are removed during soaking to prevent swelling).
Contattaci

Author:

Mr. Jacky Guo

Phone/WhatsApp:

8613722852356

Prodotti popolari
You may also like
Related Categories

Mail a questo fornitore

Oggetto:
E-mail:
messaggio:

Your message must be betwwen 20-8000 characters

Contattaci

Author:

Mr. Jacky Guo

Phone/WhatsApp:

8613722852356

Prodotti popolari
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Invia